Show simple item record

Improving PET Receptor Binding Estimates from Logan Plots Using Principal Component Analysis

dc.contributor.authorJoshi, Aniket D.en_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.contributor.authorKoeppe, Robert A.en_US
dc.date.accessioned2011-08-18T18:21:05Z
dc.date.available2011-08-18T18:21:05Z
dc.date.issued2007-12-05en_US
dc.identifier.citationJoshi, Aniket; Fessler, Jeffrey A.; Koeppe, Robert A. (2008). "Improving PET Receptor Binding Estimates from Logan Plots Using Principal Component Analysis." Journal of Cerebral Blood Flow and Metabolism 28(4): 852-865. <http://hdl.handle.net/2027.42/85912>en_US
dc.identifier.issn0271-678Xen_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85912
dc.description.abstractThis work reports a principal component analysis (PCA)-based approach for reducing bias in distribution volume ratio (DVR) estimates from Logan plots in positron emission tomography (PET). Comparison has been made of all existing bias-removal methods with the proposed PCA method, for both single-estimate PET studies and intervention studies where pre- and post-intervention estimates are made. Bias in Logan-based DVR estimates is because of the noise in the PET timeactivity curves (TACs) that propagates as correlated errors in dependent and independent variables of the Logan equation. Intervention studies show this same bias but also higher variance in DVR estimates. In this work, noise in the TACs was reduced by fitting the curves to a low-dimension PCA-based linear model, leading to reduced bias and variance in DVR. For validating the approach, TACs with realistic noise were simulated for a 11C-labeled tracer with carfentanil (CFN)-like kinetics for both single-measurement and intervention studies. Principal component analysis and existing methods were applied to the simulated data and their performance was compared by statistical analysis. The results indicated that existing methods either removed only part of the bias or reduced bias at the expense of precision. The proposed method removed ~90% of the bias while also improving precision in both single- and dual-measurement simulations. After validation of the proposed method in simulations, PCA, along with the existing methods, was applied to human [11C]CFN data acquired for both single estimation of DVR and dual-estimation intervention studies. Similar results were observed in human scans as were seen in the simulation studies.en_US
dc.publisherNPGen_US
dc.titleImproving PET Receptor Binding Estimates from Logan Plots Using Principal Component Analysisen_US
dc.typearticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDivision of Nuclear Medicine, Department of Radiology. Department of Biomedical Engineering, College of Engineering.en_US
dc.identifier.pmid18059434en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85912/1/Fessler26.pdf
dc.identifier.doi10.1038/sj.jcbfm.9600584en_US
dc.identifier.sourceJournal of Cerebral Blood Flow and Metabolismen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.