Show simple item record

Determining Total I-131 Activity Within a VoI Using SPECT, a UHE Collimator, OSEM, and a Constant Conversion Factor

dc.contributor.authorKoral, Kenneth F.en_US
dc.contributor.authorYendiki, Anastasiaen_US
dc.contributor.authorLin, Q.en_US
dc.contributor.authorDewaraja, Yuni K.en_US
dc.contributor.authorFessler, Jeffrey A.en_US
dc.date.accessioned2011-08-18T18:21:17Z
dc.date.available2011-08-18T18:21:17Z
dc.date.issued2004-06-01en_US
dc.identifier.citationKoral, K.F.; Yendiki, A.; Lin, Q.; Dewaraja, Y.K.; Fessler, J.A. (2004). "Determining Total I-131 Activity Within a VoI Using SPECT, a UHE Collimator, OSEM, and a Constant Conversion Factor." IEEE Transactions on Nuclear Science 51(3): 611-618. <http://hdl.handle.net/2027.42/85985>en_US
dc.identifier.issn0018-9499en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/85985
dc.description.abstractAccurate determination of activity within a volume of interest is needed during radiopharmaceutical therapies. Single-photon emission computed tomography(SPECT) is employed but requires a method to convert counts to activity. We use a phantom-based conversion; that is, we image an elliptical cylinder containing a sphere that has a known amount of 131-I activity inside. The regularized space alternating generalized expectation (SAGE) algorithm employing a strip-integral detector-response model was employed for reconstruction in previous patient evaluations. With that algorithm and a high-energy collimator, the estimates for sphere activity varied with changes in: 1) the level of uniform background activity in the cylinder; 2) the image resolution due to different values of the radius of rotation R; and 3) the volume of the sphere. When one used those to convert reconstructed counts within a patient tumor into an activity estimate, the resultant value may have been in error because of patient-phantom mismatch. As a potential remedy, in this paper, we use an ordered subsets expectation maximization (OSEM) algorithm with a 3-D depth-dependent detector-response model and an ultra-high-energy collimator. Results after 100 OSEM iterations and using a maximum counts registration show the estimates for sphere activity: 1) have a dependence on the level of background activity with a slope whose absolute magnitude is typically only 0.37 times that with SAGE; 2) are independent of R; and 3) are independent of sphere volume down to and including a sphere volume of 20 cm3. We conclude that using a global-average conversion factor to relate counts to activity and no volume-based correction might be reasonable with OSEM. For a test of that conclusion, target activity is estimated for an anthropomorphic phantom containing a 100 cm3 spherical tumor centrally located inferior to the lungs. With OSEM-based quantification, using: 1) a global-average conversion factor and 2) no volume-based correction, mean bias in the simulated-tumor activity estimate over 20 realizations is -7.37% (relative standard deviation =5.93%). With SAGE-based quantification using: 1) the conversion factor corresponding to the experimental estimate of ba- ckground and 2) volume-based correction, the mean bias is -10.7% (relative standard deviation =2.37%). The mean bias is smaller in a statistically significant way and relative standard deviation is not more than a factor of 2.5 bigger with OSEM compared to SAGE. In addition, with OSEM, a patient image apparently shows more highly resolved features, and the activity estimates for two tumors are increased by an average of 10%, relative to results with SAGE.en_US
dc.publisherIEEEen_US
dc.titleDetermining Total I-131 Activity Within a VoI Using SPECT, a UHE Collimator, OSEM, and a Constant Conversion Factoren_US
dc.typearticleen_US
dc.subject.hlbsecondlevelBiomedical Engineeringen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Radiology.en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/85985/1/Fessler57.pdf
dc.identifier.doi10.1109/TNS.2004.829605en_US
dc.identifier.sourceIEEE Transactions on Nuclear Scienceen_US
dc.owningcollnameElectrical Engineering and Computer Science, Department of (EECS)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.