Evaluation of Dosimetric Unvertainties and Transit Dosimetry Feasibility in Pulmonary Stereotactic Body Radiotherapy (SBRT).

dc.contributor.authorHsu, Shu-Huien_US
dc.date.accessioned2011-09-15T17:17:47Z
dc.date.availableNO_RESTRICTIONen_US
dc.date.available2011-09-15T17:17:47Z
dc.date.issued2011en_US
dc.date.submitteden_US
dc.identifier.urihttps://hdl.handle.net/2027.42/86513
dc.description.abstractThe aims of this dissertation were to develop a method with improved accuracy for various heterogeneous geometries and to evaluate the feasibility of using EPID transit dosimetry for error detection. This dissertation examined phantom geometries with an emphasis on a tumor-in-lung geometry that may occur in hypo-fractionated SBRT treatments. For dose investigation in heterogeneous geometries, a multi-planar film measurement system was used with a measurement accuracy (within 3%) by using specific procedures to reduce the film perturbation in a low density medium. Measurements were used to validate a Monte Carlo (MC) method, and the results indicated that this MC method can be used as a reference to validate other calculation algorithms or to evaluate the doses delivered to patients for lung treatment. For developing an error detection method, a commercial electronic portal imaging device (EPID) composed of amorphous silicon was characterized for dosimetry application. A general calibration method was explored to use this device as a water-equivalent dosimeter, allowing for direct comparison to calculated doses from treatment planning systems. The calibration method was validated for a range of situations, field shapes, and intensities. The EPID transit dosimetry was sensitive to delivery errors, such as variations in treatment field shape, machine output and patient setup. The correlation between in-patient and transit dose variations may be established and used to determine acceptance or rejection criteria when the error is found. This dissertation showed the potential of using EPID dosimetry during treatment for on-line error correction and for estimating the in-patient dose error.en_US
dc.language.isoen_USen_US
dc.subjectRadiotherapy in Lung Tumorsen_US
dc.subjectInterface Dosimetryen_US
dc.subjectDose Verificationen_US
dc.titleEvaluation of Dosimetric Unvertainties and Transit Dosimetry Feasibility in Pulmonary Stereotactic Body Radiotherapy (SBRT).en_US
dc.typeThesisen_US
dc.description.thesisdegreenamePhDen_US
dc.description.thesisdegreedisciplineNuclear Engineering & Radiological Sciencesen_US
dc.description.thesisdegreegrantorUniversity of Michigan, Horace H. Rackham School of Graduate Studiesen_US
dc.contributor.committeememberKearfott, Kimberlee J.en_US
dc.contributor.committeememberMoran, Jean Marieen_US
dc.contributor.committeememberBielajew, Alex F.en_US
dc.contributor.committeememberGoodsitt, Mitchell M.en_US
dc.contributor.committeememberRoberson, Peter L.en_US
dc.subject.hlbsecondlevelNuclear Engineering and Radiological Sciencesen_US
dc.subject.hlbtoplevelEngineeringen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/86513/1/shuihsu_1.pdf
dc.owningcollnameDissertations and Theses (Ph.D. and Master's)


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.