Simple pressure-tuned Fabry–Pérot interferometer

dc.contributor.authorHansis, E.en_US
dc.contributor.authorCubel, T.en_US
dc.contributor.authorChoi, J.-H.en_US
dc.contributor.authorGuest, J. R.en_US
dc.contributor.authorRaithel, Georgen_US
dc.date.accessioned2011-11-15T16:10:54Z
dc.date.available2011-11-15T16:10:54Z
dc.date.issued2005-03en_US
dc.identifier.citationHansis, E.; Cubel, T.; Choi, J.-H.; Guest, J. R.; Raithel, G. (2005). "Simple pressure-tuned Fabry–Pérot interferometer." Review of Scientific Instruments 76(3): 033105-033105-3. <http://hdl.handle.net/2027.42/87892>en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/87892
dc.description.abstractA simple, compact and inexpensive pressure-tuned Fabry–Pérot interferometer is presented. It is used as a laser locking reference for optical frequencies where the use of an atomic reference is impractical. The scanning range is several GHz. Absolute positioning of the interferometer with an accuracy of 7 MHz7MHz rms over a range of 2 GHz2GHz is possible. The instrument is temperature stabilized and shows long-term drift of 16 MHz16MHz rms over 48 h48h.en_US
dc.publisherThe American Institute of Physicsen_US
dc.rights© The American Institute of Physicsen_US
dc.titleSimple pressure-tuned Fabry–Pérot interferometeren_US
dc.typeArticleen_US
dc.subject.hlbsecondlevelPhysicsen_US
dc.subject.hlbtoplevelScienceen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumFOCUS Center, Department of Physics, University of Michigan, Ann Arbor, Michigan 48109en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/87892/2/033105_1.pdf
dc.identifier.doi10.1063/1.1866237en_US
dc.identifier.sourceReview of Scientific Instrumentsen_US
dc.identifier.citedreferenceW. Demtröder, Laser Spectroscopy (Springer, New York, 1998).en_US
dc.identifier.citedreferenceJ.R. Guest, J.-H. Choi, E. Hansis, A.P. Povilus, and G. Raithel, Phys. Rev. Lett. (in press).en_US
dc.identifier.citedreferenceB. K. Teo, D. Feldbaum, T. Cubel, J. R. Guest, P. R. Berman, and G. Raithel, Phys. Rev. A 68, 053407 (2003).en_US
dc.identifier.citedreferenceR. Mock, B. Hillebrands, and R. Sandercock, J. Phys. E 20, 656 (1987).en_US
dc.identifier.citedreferenceD. A. Rockwell, R. F. Benjamin, and T. J. Greytak, J. Low Temp. Phys. 18, 389 (1975).en_US
dc.identifier.citedreferenceJ. E. Mack, D. P. McNutt, F. L. Roesler, and R. Chabbal, Appl. Opt. 2, 873 (1963).en_US
dc.identifier.citedreferenceM. Hercher, Appl. Opt. 7, 951 (1968).en_US
dc.identifier.citedreferenceJ. R. Johnson, Appl. Opt. 7, 1061 (1968).en_US
dc.identifier.citedreferenceInternational Critical Tables of Numerical Data, edited by E. W. Washburn (Knovel, Norwich, NY, 2003).en_US
dc.identifier.citedreferenceJ. Yata, M. Hori, H. Kawakatsu, and T. Minamiyama, Int. J. Thermophys. 17, 65 (1996).en_US
dc.owningcollnamePhysics, Department of


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.