Show simple item record

Cardiac Device‐Related Endocarditis Complicated by Spinal Abscess

dc.contributor.authorRodriguez, Yasseren_US
dc.contributor.authorGreenspon, Arnold J.en_US
dc.contributor.authorSohail, Muhammad R.en_US
dc.contributor.authorCarrillo, Roger G.en_US
dc.date.accessioned2012-03-16T15:54:03Z
dc.date.available2013-05-01T17:24:42Zen_US
dc.date.issued2012-03en_US
dc.identifier.citationRodriguez, Yasser ; Greenspon, Arnold J. ; Sohail, Muhammad R. ; Carrillo, Roger G. (2012). "Cardiac Deviceâ Related Endocarditis Complicated by Spinal Abscess." Pacing and Clinical Electrophysiology 35(3). <http://hdl.handle.net/2027.42/90084>en_US
dc.identifier.issn0147-8389en_US
dc.identifier.issn1540-8159en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/90084
dc.publisherBlackwell Publishing Incen_US
dc.publisherWiley Periodicals, Inc.en_US
dc.subject.otherPacemakeren_US
dc.subject.otherInfectionen_US
dc.subject.otherDefibrillatorsen_US
dc.subject.otherAbscessen_US
dc.subject.otherSpineen_US
dc.subject.otherEndocarditisen_US
dc.titleCardiac Device‐Related Endocarditis Complicated by Spinal Abscessen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelPhysiologyen_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Internal Medicine, University of Michigan, Ann Arbor, Michiganen_US
dc.contributor.affiliationotherDepartment of Internal Medicine, Division of Cardiology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvaniaen_US
dc.contributor.affiliationotherDepartment of Cardiothoracic Surgery, University of Miami, Miami, Floridaen_US
dc.contributor.affiliationotherDepartment of Internal Medicine, Division of Infectious Diseases, Mayo Clinic College of Medicine, Rochester, Minnesotaen_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/90084/1/j.1540-8159.2011.03288.x.pdf
dc.identifier.doi10.1111/j.1540-8159.2011.03288.xen_US
dc.identifier.sourcePacing and Clinical Electrophysiologyen_US
dc.identifier.citedreferenceChambers ST. Diagnosis and management of staphylococcal infections of pacemakers and cardiac defibrillators. Intern Med J 2005; 35: S63 – S71.en_US
dc.identifier.citedreferenceCorey RG, Lalani T. Risk of intravascular cardiac device infections in patients with bacteraemia: Impact on device removal. Int J Antimicrob Agents 2008; 32: S S26 – SS29.en_US
dc.identifier.citedreferenceCorman LC, Levison ME. Sustained bacteremia and transvenous cardiac pacemakers. JAMA 1975; 233: 264 – 266.en_US
dc.identifier.citedreferenceSohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, Steckelberg JM, et al. Risk factor analysis of permanent pacemaker infection. Clin Infect Dis 2007; 45: 166 – 173.en_US
dc.identifier.citedreferenceSchwartz IS, Pervez N. Bacterial endocarditis associated with a permanent transvenous cardiac pacemaker. JAMA 1971; 218: 736 – 737.en_US
dc.identifier.citedreferenceBaddour LM, Epstein AE, Erickson CC, Knight BP, Levison ME, Lockhart PB, Masoudi FA, et al. Update on cardiovascular implantable electronic device infections and their management: A scientific statement from the American Heart Association. Circulation 2010; 121: 458 – 477.en_US
dc.identifier.citedreferenceLe KY, Sohail MR, Friedman PA, Uslan DZ, Cha SS, Hayes DL, Wilson WR, et al. Clinical predictors of cardiovascular implantable electronic device‐related infective endocarditis. Pacing Clin Electrophysiol 2011; 34: 450 – 459.en_US
dc.identifier.citedreferenceSohail MR, Hussain S, Le KY, Dib C, Lohse CM, Friedman PA, Hayes DL, et al. Risk factors associated with early‐ versus late‐onset implantable cardioverter‐defibrillator infections. J Interv Card Electrophysiol 2011; 31: 171 – 183.en_US
dc.identifier.citedreferenceKurtz SM, Ochoa JA, Lau E, Shkolnikov Y, Pavri BB, Frisch D, Greenspon AJ. Implantation trends and patient profiles for pacemakers and implantable cardioverter defibrillators in the United States: 1993–2006. Pacing Clin Electrophysiol 2010; 33: 705 – 711en_US
dc.identifier.citedreferenceLe KY, Sohail MR, Friedman PA, Uslan DZ, Cha SS, Hayes DL, Wilson WR, et al. Clinical predictors of cardiovascular implantable electronic device‐related infective endocarditis. Pacing Clin Electrophysiol 2011; 34: 450 – 459.en_US
dc.identifier.citedreferenceBaddour LM, Epstein AE, Erickson CC, Knight BP, Levison ME, Lockhart PB, Masoudi FA, et al. Update on cardiovascular implantable electronic device infections and their management. A scientific statement from the American Heart Association. Circulation 2010; 121: 458 – 477en_US
dc.identifier.citedreferenceWazni O, Epstein LM, Carrillo RG, Love C, Adler SW, Riggio DW, Karim SS, et al. Lead extraction in the contemporary setting: The lexicon study. J Am Coll Cardiol 2010; 55: 579 – 586.en_US
dc.identifier.citedreferenceSohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, Steckelberg JM, et al. Management and outcome of permanent pacemaker and implantable cardioverter‐defibrillator infections. J Am Coll Cardiol 2007; 49: 1851 – 1859.en_US
dc.identifier.citedreferenceSohail MR, Henrikson CA, Braid‐Forbes MJ, Forbes KF, Lerner DJ. Mortality and cost associated with cardiovascular implantable electronic device infections. Arch Intern Med 2011; 1821 – 1828.en_US
dc.identifier.citedreferenceCabell CH, Heidenreich PA, Chu VH, Moore CM, Stryjewski ME, Corey GR, Fowler VG Jr. Increasing rates of cardiac device infections among Medicare beneficiaries: 1990–1999. Am Heart J 2004; 147: 582 – 586.en_US
dc.identifier.citedreferenceVoigt A, Shalaby A, Saba S. Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coll Cardiol 2006; 48: 590 – 591.en_US
dc.identifier.citedreferenceSohail MR, Uslan DZ, Khan AH, Friedman PA, Hayes DL, Wilson WR, Steckelberg JM, et al. Infective endocarditis complicating permanent pacemaker and implantable cardioverter‐defibrillator infection. Mayo Clin Proc 2008; 83: 46 – 53.en_US
dc.identifier.citedreferenceGreenspon AJ, Patel JD, Lau E, Ochoa JA, Frisch D, Ho RT, Pavri BB, et al. Sixteen year trends in the infection burden for pacemakers and cardioverter‐defibrillators in the United States: 1993–2008. J Am Coll Cardiol (in press). 2011; 58: 1001 – 1006en_US
dc.identifier.citedreferenceVoigt A, Shalaby A, Saba S. Continued rise in rates of cardiovascular implantable electronic device infections in the United States: Temporal trends and causative insights. Pacing Clin Electrophysiol 2010; 33: 414 – 420.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.