Potential for unreliable interpretation of EEG recorded with microelectrodes

dc.contributor.authorStacey, William C.en_US
dc.contributor.authorKellis, Spenceren_US
dc.contributor.authorGreger, Bradleyen_US
dc.contributor.authorButson, Christopher R.en_US
dc.contributor.authorPatel, Paras R.en_US
dc.contributor.authorAssaf, Trevoren_US
dc.contributor.authorMihaylova, Temenuzhkaen_US
dc.contributor.authorGlynn, Simonen_US
dc.date.accessioned2013-08-02T20:51:49Z
dc.date.available2014-10-06T19:17:44Zen_US
dc.date.issued2013-08en_US
dc.identifier.citationStacey, William C.; Kellis, Spencer; Greger, Bradley; Butson, Christopher R.; Patel, Paras R.; Assaf, Trevor; Mihaylova, Temenuzhka; Glynn, Simon (2013). "Potential for unreliable interpretation of EEG recorded with microelectrodes." Epilepsia 54(8): 1391-1401. <http://hdl.handle.net/2027.42/99089>en_US
dc.identifier.issn0013-9580en_US
dc.identifier.issn1528-1167en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/99089
dc.publisherOxford University Pressen_US
dc.publisherWiley Periodicals, Inc.en_US
dc.subject.otherImpedanceen_US
dc.subject.otherElectrodesen_US
dc.subject.otherHigh Frequency Oscillationsen_US
dc.subject.otherElectrocorticographyen_US
dc.titlePotential for unreliable interpretation of EEG recorded with microelectrodesen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelMedicine (General)en_US
dc.subject.hlbtoplevelHealth Sciencesen_US
dc.description.peerreviewedPeer Revieweden_US
dc.identifier.pmid23647099en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/99089/1/epi12202.pdf
dc.identifier.doi10.1111/epi.12202en_US
dc.identifier.sourceEpilepsiaen_US
dc.identifier.citedreferenceQuiroga RQ, Reddy L, Kreiman G, Koch C, Fried I. ( 2005 ) Invariant visual representation by single neurons in the human brain. Nature 435: 1102 – 1107.en_US
dc.identifier.citedreferenceBenbadis SR, LaFrance WC Jr, Papandonatos GD, Korabathina K, Lin K, Kraemer HC. ( 2009 ) Interrater reliability of EEG‐video monitoring. Neurology 73: 843 – 846.en_US
dc.identifier.citedreferenceBlanco JA, Stead M, Krieger A, Viventi J, Marsh WR, Lee KH, Worrell GA, Litt B. ( 2010 ) Unsupervised classification of high‐frequency oscillations in human neocortical epilepsy and control patients. J Neurophysiol 104: 2900 – 2912.en_US
dc.identifier.citedreferenceBlanco JA, Stead M, Krieger A, Stacey W, Maus D, Marsh E, Viventi J, Lee KH, Marsh R, Litt B, Worrell GA. ( 2011 ) Data mining neocortical high‐frequency oscillations in epilepsy and controls. Brain 134: 2948 – 2959.en_US
dc.identifier.citedreferenceBragin A, Wilson CL, Staba RJ, Reddick M, Fried I, Engel J Jr. ( 2002 ) Interictal high‐frequency oscillations (80–500 Hz) in the human epileptic brain: entorhinal cortex. Ann Neurol 52: 407 – 415.en_US
dc.identifier.citedreferenceBrown MW 3rd, Porter BE, Dlugos DJ, Keating J, Gardner AB, Storm PB Jr, Marsh ED. ( 2007 ) Comparison of novel computer detectors and human performance for spike detection in intracranial EEG. Clin Neurophysiol 118: 1744 – 1752.en_US
dc.identifier.citedreferenceChatillon CE, Zelmann R, Bortel A, Avoli M, Gotman J. ( 2011 ) Contact size does not affect high frequency oscillation detection in intracerebral EEG recordings in a rat epilepsy model. Clin Neurophysiol 122: 1701 – 1705.en_US
dc.identifier.citedreferenceDavis TS, Parker RA, House PA, Bagley E, Wendelken S, Normann RA, Greger B. ( 2012 ) Spatial and temporal characteristics of V1 microstimulation during chronic implantation of a microelectrode array in a behaving macaque. J Neural Eng 9: 065003.en_US
dc.identifier.citedreferenceHochberg LR, Serruya MD, Friehs GM, Mukand JA, Saleh M, Caplan AH, Branner A, Chen D, Penn RD, Donoghue JP. ( 2006 ) Neuronal ensemble control of prosthetic devices by a human with tetraplegia. Nature 442: 164 – 171.en_US
dc.identifier.citedreferenceLathi BP. ( 2005 ) Linear systems and signals. Oxford University Press, New York.en_US
dc.identifier.citedreferenceLe Van Quyen M, Staba R, Bragin A, Dickson C, Valderrama M, Fried I, Engel J. ( 2010 ) Large‐scale microelectrode recordings of high‐frequency gamma oscillations in human cortex during sleep. J Neurosci 30: 7770 – 7782.en_US
dc.identifier.citedreferenceMcAdams ET, Jossinet J, Subramanian R, McCauley RG. ( 2006 ) Characterization of gold electrodes in phosphate buffered saline solution by impedance and noise measurements for biological applications. Conf Proc IEEE Eng Med Biol Soc 1: 4594 – 4597.en_US
dc.identifier.citedreferenceNormann RA. ( 2007 ) Technology insight: future neuroprosthetic therapies for disorders of the nervous system. Nat Clin Pract Neurol 3: 444 – 452.en_US
dc.identifier.citedreferenceSchevon CA, Trevelyan AJ, Schroeder CE, Goodman RR, McKhann G Jr, Emerson RG. ( 2009 ) Spatial characterization of interictal high frequency oscillations in epileptic neocortex. Brain 132: 3047 – 3059.en_US
dc.identifier.citedreferenceSchevon CA, Goodman RR, McKhann G Jr, Emerson RG. ( 2010 ) Propagation of epileptiform activity on a submillimeter scale. J Clin Neurophysiol 27: 406 – 411.en_US
dc.identifier.citedreferenceSchevon CA, Weiss SA, McKhann G Jr, Goodman RR, Yuste R, Emerson RG, Trevelyan AJ. ( 2012 ) Evidence of an inhibitory restraint of seizure activity in humans. Nat Commun 3: 1060.en_US
dc.identifier.citedreferenceStaba RJ, Wilson CL, Bragin A, Fried I, Engel J Jr. ( 2002 ) Quantitative analysis of high‐frequency oscillations (80–500 Hz) recorded in human epileptic hippocampus and entorhinal cortex. J Neurophysiol 88: 1743 – 1752.en_US
dc.identifier.citedreferenceStacey WC, Kellis S, Patel PR, Greger B, Butson CR. ( 2012 ) Signal distortion from microelectrodes in clinical EEG acquisition systems. J Neural Eng 9: 056007.en_US
dc.identifier.citedreferenceStead M, Bower M, Brinkmann BH, Lee K, Marsh WR, Meyer FB, Litt B, Van Gompel J, Worrell GA. ( 2010 ) Microseizures and the spatiotemporal scales of human partial epilepsy. Brain 133: 2789 – 2797.en_US
dc.identifier.citedreferenceTruccolo W, Donoghue JA, Hochberg LR, Eskandar EN, Madsen JR, Anderson WS, Brown EN, Halgren E, Cash SS. ( 2011 ) Single‐neuron dynamics in human focal epilepsy. Nat Neurosci 14: 635 – 641.en_US
dc.identifier.citedreferenceVan Gompel JJ, Stead SM, Giannini C, Meyer FB, Marsh WR, Fountain T, So E, Cohen‐Gadol A, Lee KH, Worrell GA. ( 2008 ) Phase I trial: safety and feasibility of intracranial electroencephalography using hybrid subdural electrodes containing macro‐ and microelectrode arrays. Neurosurg Focus 25: E23.en_US
dc.identifier.citedreferenceWong S, Gardner AB, Krieger AM, Litt B. ( 2007 ) A stochastic framework for evaluating seizure prediction algorithms using hidden Markov models. J Neurophysiol 97: 2525 – 2532.en_US
dc.identifier.citedreferenceWorrell GA, Jerbi K, Kobayashi K, Lina JM, Zelmann R, Le Van Quyen M. ( 2012 ) Recording and analysis techniques for high‐frequency oscillations. Prog Neurobiol 98: 265 – 278.en_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe library materials in a way that respects the people and communities who create, use, and are represented in our collections. Report harmful or offensive language in catalog records, finding aids, or elsewhere in our collections anonymously through our metadata feedback form. More information at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.