Work Description
Title: CT Data of UMMP VP 68409, Plesiadapis gingerichi, incisor fragment (holotype) Open Access Deposited
Attribute | Value |
---|---|
Methodology |
|
Description |
|
Creator | |
Depositor |
|
Contact information | |
Discipline | |
Keyword | |
Related items in Deep Blue Documents | |
Resource type | |
Last modified |
|
Published |
|
Language | |
DOI |
|
License |
|
(2023). CT Data of UMMP VP 68409, Plesiadapis gingerichi, incisor fragment (holotype) [Data set], University of Michigan - Deep Blue Data. https://doi.org/10.7302/tgn3-8234
Relationships
- In Collection:
Files (Count: 5; Size: 507 MB)
Thumbnailthumbnail-column | Title | Original Upload | Last Modified | File Size | Access | Actions |
---|---|---|---|---|---|---|
UMMP_VP_68409_Plesiadapis_ginger...l.jpg | 2023-11-03 | 2023-11-03 | 67.1 KB | Open Access |
|
|
_README.txt | 2023-11-03 | 2023-11-03 | 1.53 KB | Open Access |
|
|
_LICENSE.txt | 2023-11-03 | 2023-11-03 | 6.18 KB | Open Access |
|
|
UMMP_VP_68409_Plesiadapis_ginger...T.md5 | 2023-11-03 | 2023-11-03 | 196 Bytes | Open Access |
|
|
UMMP_VP_68409_Plesiadapis_ginger...T.zip | 2023-11-03 | 2023-11-03 | 507 MB | Open Access |
|
DescriptionString: Reconstructed CT slices for Incisor frag. of Plesiadapis gingerichi (University of Michigan Museum of Paleontology catalog number UMMP 68409) as a series of TIFF images. Raw projections are not included in this dataset. The reconstructed slice data from the scan are offered here as a series of unsigned 16-bit integer TIFF images. The upper left corner of the first image (*_0000.tif) is the XYZ origin.
MethodString: Specimen UMMP 68409_Plesiadapis gingerichi_Incisor frag. was scanned with a Nikon XT H 225ST uCT system housed in the Department of Earth and Environmental Sciences at the University of Michigan. Scans were collected with the following settings: energy settings, 180 kV, 88 uA; source to object distance, 88.72369 mm; source to detector distance, 1104.0 mm; scanned with 1600 projections; voxel size, x = 0.01607314 mm y = 0.01607314 mm z = 0.01607314 mm; slice dimension (in pixels), x = 671, y = 533; number of slices, 793 16-bit TIFF images. Original floating point grey values were scaled to span the unsigned 16-bit integer range using an offset of 19.236919403076172 and a scale factor of 92.84627384275106, where 16output = SCALE * (32input + OFFSET). Additional metadata can be found in the xtekct, ctprofile.xml, and UMMPCombinedMetadata.json files.
License: Usage of the associated data is restricted. The terms of use as of date of metadata creation (2023-10-30 08:50:29.602587) are included in the file _LICENSE.txt. Please see https://umorf.ummp.lsa.umich.edu/wp/ct-terms/ for current terms, as these may have changed.