Work Description
Title: CT Data of UMMP R 102, Physeter tooth (occlusal part of sectioned tooth) Open Access Deposited
Attribute | Value |
---|---|
Methodology |
|
Description |
|
Creator | |
Depositor |
|
Contact information | |
Discipline | |
Keyword | |
Date coverage |
|
Citations to related material |
|
Resource type | |
Last modified |
|
Published |
|
Language | |
DOI |
|
License |
|
(2022). CT Data of UMMP R 102, Physeter tooth (occlusal part of sectioned tooth) [Data set], University of Michigan - Deep Blue Data. https://doi.org/10.7302/a8wd-zf85
Relationships
- In Collection:
Files (Count: 5; Size: 1.86 GB)
Thumbnailthumbnail-column | Title | Original Upload | Last Modified | File Size | Access | Actions |
---|---|---|---|---|---|---|
UMMP_R_102_Physeter_tooth_occlus...l.jpg | 2022-09-19 | 2022-09-19 | 81 KB | Open Access |
|
|
UMMP_R_102_Physeter_tooth_occlus...T.zip | 2022-09-19 | 2022-09-19 | 1.86 GB | Open Access |
|
|
UMMP_R_102_Physeter_tooth_occlus...T.md5 | 2022-09-19 | 2022-09-19 | 187 Bytes | Open Access |
|
|
_LICENSE.txt | 2022-09-19 | 2022-09-19 | 6.18 KB | Open Access |
|
|
_README.txt | 2022-09-19 | 2022-09-19 | 1.55 KB | Open Access |
|
"MethodString": "Specimen UMMP_R_102_Physeter_tooth, occlusal part of sectioned tooth was scanned with a Nikon XT H 225ST uCT system housed in the Department of Earth and Environmental Sciences at the University of Michigan. Scans were collected with the following settings: energy settings, 115 kV, 143 uA; source to object distance, 289.0007 mm; source to detector distance, 1105.0 mm; scanned with 3141 projections; voxel size, x = 0.05230783 mm y = 0.05230783 mm z = 0.05230783 mm; slice dimension (in pixels), x = 985, y = 1051; number of slices, 996 16-bit TIFF images. Original floating point grey values were scaled to span the unsigned 16-bit integer range using an offset of 18.0684 and a scale factor of 651.037, where 16output = SCALE * (32input + OFFSET). Additional metadata can be found in the xtekct, ctprofile.xml, and UMMPCombinedMetadata.json files."
"DescriptionString": "Reconstructed CT slices for tooth, occlusal part of sectioned tooth of Physeter (University of Michigan Museum of Paleontology catalog number UMMP_R_102) as a series of TIFF images. Raw projections are not included in this dataset. The reconstructed slice data from the scan are offered here as a series of unsigned 16-bit integer TIFF images. The upper left corner of the first image (*_0000.tif) is the XYZ origin."
"License": "Usage of the associated data is restricted. The terms of use as of date of metadata creation (2022-09-19 17:14:17.783257) are included in the file _LICENSE.txt. Please see https://umorf.ummp.lsa.umich.edu/wp/ct-terms/ for current terms, as these may have changed."