On the utility of an in-core fast neutron generator
(Elsevier, 1978-11-01)
An examination of the flux magnitudes reported for a LiOD-D2O converter (thermal to 14 MeV neutrons) indicates that such a device offers little if any advantage over fission spectrum neutrons.
Multiplet structure of 210Bi from the 209Bi(d, p) and 209Bi([alpha], 3He) reactions
(Elsevier, 1972-05-15)
Levels in 210Bi have been studied by the 209Bi(d, p)210Bi reaction at 19 MeV and the 209Bi([alpha], 3He)210Bi reaction at 58 MeV. Transfer l-values have been determined and spectroscopic strengths deduced by comparison ...
What can we learn from semi-inclusive rapidity correlations?
(Elsevier, 1975-02-10)
We study a general formulation of semi-inclusive two-particle rapidity correlations for short-range models. We use it to compare with the 205 GeV NAL Bubble Chamber data different decay distributions for independently ...
Neutron-proton elastic scattering from 5 to 30 GeV/c
(Elsevier, 1971-07-01)
The differential cross section for neutron-proton elastic scattering was measured in the diffraction region with incident neutron momenta between 5 and 30 GeV/c. The experiment was an optical-spark-chamber-counter experiment ...
An investigation of nonlinear xenon oscillation by method of averaging
(Elsevier, 1973-12)
A nonlinear analysis of xenon-temperature controlled nuclear reactor dynamics is presented. The set of equations in question belongs to a general class of rate equations with quadratic nonlinearities. Boundedness of the ...
Physical meson-baryon scattering in the canonical algebra
(Elsevier, 1972-11-01)
A recalculation of the meson-baryon scattering lengths yielded a good agreement with experimental data and a qualitative agreement with a previous calculation of Von Hippel and Kim. The connected matrix element of the ...
Variable range cluster model of exciton migration: Dimensionality and critical exponents for naphthalene
(Elsevier, 1979-01)
Relative luminescence intensities for randomly substituted ternary systems with two major components and a minor one (sensor), for four triplet and one singlet exciton systems, identify the maximal effective exciton ...
Experimental and calculated photopeak efficiencies for a coaxial Ge(Li) detector
(Elsevier, 1971-05-15)
Experimental and calculated photopeak efficiencies have been obtained for a 32 cm3 true coaxial Ge(Li) detector at four distances: 2 cm, 5 cm, 10 cm and 20 cm. A comparison of these results is presented.
Inclusive and semi-inclusive pion production in pp collisions at 102 and 400 GeV/c
(Elsevier, 1976-04-26)
We present a comparative study of inclusive and semi-inclusive pion production in pp collisions at 102 and 400 GeV/c. In particular, we examine the correlation between transverse and longitudinal momentum variables and the ...
The isochronous cyclotron and high-resolution nuclear spectroscopy
(Elsevier, 1970-02-15)