Effect of dose level on radiologists' detection of microcalcifications in digital breast tomosynthesis: An observer study with breast phantoms.
Chan, HP; Helvie, MA; Klein, M.D., F.A.C.R., KA; Mclaughlin, C; Neal, CH; Oudsema, R; Rahman, WT; Roubidoux, MA; Hadjiiski, LM; Zhou, C; Samala, RK
2022-01-01
View/ Open
Medical Physics - 2023 - Chan - Deep learning denoising of digital breast tomosynthesis Observer performance study of the.pdf
Published version

(1.3MB
PDF)Published version
Abstract
Objectives: To compare radiologists’ sensitivity, confidence level, and reading efficiency of detecting microcalcifications in digital breast tomosynthesis (DBT) at two clinically relevant dose levels. Materials and Methods: Six 5-cm-thick heterogeneous breast phantoms embedded with a total of 144 simulated microcalcification clusters of four speck sizes were imaged at two dose modes by a clinical DBT system. The DBT volumes at the two dose levels were read independently by six MQSA radiologists and one fellow with 1–33 years (median 12 years) of experience in a fully-crossed counter-balanced manner. The radiologist located each potential cluster and rated its conspicuity and his/her confidence that the marked location contained a cluster. The differences in the results between the two dose modes were analyzed by two-tailed paired t-test. Results: Compared to the lower-dose mode, the average glandular dose in the higher-dose mode for the 5-cm phantoms increased from 1.34 to 2.07 mGy. The detection sensitivity increased for all speck sizes and significantly for the two smaller sizes (p <0.05). An average of 13.8% fewer false positive clusters was marked. The average conspicuity rating and the radiologists’ confidence level were higher for all speck sizes and reached significance (p <0.05) for the three larger sizes. The average reading time per detected cluster reduced significantly (p <0.05) by an average of 13.2%. Conclusion: For a 5-cm-thick breast, an increase in average glandular dose from 1.34 to 2.07 mGy for DBT imaging increased the conspicuity of microcalcifications, improved the detection sensitivity by radiologists, increased their confidence levels, reduced false positive detections, and increased the reading efficiency.Publisher
Elsevier
ISSN
1076-6332 1878-4046
Deep Blue DOI
Other DOIs
PMID
32950384
Subjects
Digital breast tomosynthesis dose microcalcifications observer study Breast Breast Neoplasms Calcinosis Female Humans Male Mammography Phantoms, Imaging Radiologists
Types
Article
Metadata
Show full item recordCollections
Showing items related by title, author, creator and subject.
-
Katz, S. J.; Hawley, S. T.; Abrahamse, P.; Morrow, M.; Friese, C. R.; Alderman, A. K.; Griggs, J. J.; Hamilton, A. S.; Graff, J. J.; Hofer, T. P. (2010-10)
-
Ben-David, Merav A.; Kleer, Celina G.; Paramagul, Chintana; Griffith, Kent A.; Pierce, Lori J. (Wiley Subscription Services, Inc., A Wiley Company, 2006-01-01)
-
Creighton, Chad J; Cordero, Kevin E; Larios, Jose M; Miller, Rebecca S; Johnson, Michael D; Chinnaiyan, Arul M; Lippman, Marc E; Rae, James M (2006-04-07)
Remediation of Harmful Language
The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.