Capillary liquid chromatography with MS 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats
dc.contributor.author | Baseski, Holly M. | en_US |
dc.contributor.author | Watson, Christopher J. | en_US |
dc.contributor.author | Cellar, Nicholas A. | en_US |
dc.contributor.author | Shackman, Jonathan G. | en_US |
dc.contributor.author | Kennedy, Robert T. | en_US |
dc.date.accessioned | 2006-04-19T14:16:14Z | |
dc.date.available | 2006-04-19T14:16:14Z | |
dc.date.issued | 2005-02 | en_US |
dc.identifier.citation | Baseski, Holly M.; Watson, Christopher J.; Cellar, Nicholas A.; Shackman, Jonathan G.; Kennedy, Robert T. (2005)."Capillary liquid chromatography with MS 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats." Journal of Mass Spectrometry 40(2): 146-153. <http://hdl.handle.net/2027.42/35204> | en_US |
dc.identifier.issn | 1076-5174 | en_US |
dc.identifier.issn | 1096-9888 | en_US |
dc.identifier.uri | https://hdl.handle.net/2027.42/35204 | |
dc.identifier.uri | http://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=15706617&dopt=citation | en_US |
dc.description.abstract | In vivo microdialysis sampling was coupled to capillary liquid chromatography (LC)/electrospray ionization quadrupole ion trap mass spectrometry (MS) to monitor [Met]enkephalin and [Leu]enkephalin in the striatum of anesthetized and freely–moving rats. The LC system utilized a high-pressure pump to load 2.5 µl samples and desalt the 25 µm i.d. by 2 cm long column in 12 min. Samples were eluted with a separate pump at ∼100 nl min −1 . A rapid gradient effectively separated the endogenous neuropeptides in 4 min. A comparison was made for operating the mass spectrometer in the MS 2 and MS 3 modes for detection of the peptides. In standard solutions, the detection limits were similar at 1–2 pM (2–4 amol injected); however, the reproducibility was improved with MS 3 as the relative standard deviation was <5% compared with 20% for MS 2 for 60 pM samples. For dialysate solutions, reconstructed ion chromatograms and tandem mass spectra had much higher signal-to-noise ratios in the MS 3 mode, resulting in more confident detection at in vivo concentrations. The method was successfully used to monitor the peptides under basal conditions and with stimulation of peptide secretion by infusion of elevated K + concentration. Copyright © 2005 John Wiley & Sons, Ltd. | en_US |
dc.format.extent | 192000 bytes | |
dc.format.extent | 3118 bytes | |
dc.format.mimetype | application/pdf | |
dc.format.mimetype | text/plain | |
dc.language.iso | en_US | |
dc.publisher | John Wiley & Sons, Ltd. | en_US |
dc.subject.other | Chemistry | en_US |
dc.subject.other | Analytical Chemistry and Spectroscopy | en_US |
dc.title | Capillary liquid chromatography with MS 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats | en_US |
dc.type | Article | en_US |
dc.rights.robots | IndexNoFollow | en_US |
dc.subject.hlbsecondlevel | Chemistry | en_US |
dc.subject.hlbtoplevel | Science | en_US |
dc.description.peerreviewed | Peer Reviewed | en_US |
dc.contributor.affiliationum | Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USA | en_US |
dc.contributor.affiliationum | Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USA | en_US |
dc.contributor.affiliationum | Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USA | en_US |
dc.contributor.affiliationum | Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USA | en_US |
dc.contributor.affiliationum | Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USA ; Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, USA ; Department of Chemistry, University of Michigan, 930 N. University Avenue, Ann Arbor, Michigan 48109-1055, USA. | en_US |
dc.identifier.pmid | 15706617 | en_US |
dc.description.bitstreamurl | http://deepblue.lib.umich.edu/bitstream/2027.42/35204/1/733_ftp.pdf | en_US |
dc.identifier.doi | http://dx.doi.org/10.1002/jms.733 | en_US |
dc.identifier.source | Journal of Mass Spectrometry | en_US |
dc.owningcollname | Interdisciplinary and Peer-Reviewed |
Files in this item
Remediation of Harmful Language
The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.
Accessibility
If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.