Show simple item record

Capillary liquid chromatography with MS 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats

dc.contributor.authorBaseski, Holly M.en_US
dc.contributor.authorWatson, Christopher J.en_US
dc.contributor.authorCellar, Nicholas A.en_US
dc.contributor.authorShackman, Jonathan G.en_US
dc.contributor.authorKennedy, Robert T.en_US
dc.date.accessioned2006-04-19T14:16:14Z
dc.date.available2006-04-19T14:16:14Z
dc.date.issued2005-02en_US
dc.identifier.citationBaseski, Holly M.; Watson, Christopher J.; Cellar, Nicholas A.; Shackman, Jonathan G.; Kennedy, Robert T. (2005)."Capillary liquid chromatography with MS 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving rats." Journal of Mass Spectrometry 40(2): 146-153. <http://hdl.handle.net/2027.42/35204>en_US
dc.identifier.issn1076-5174en_US
dc.identifier.issn1096-9888en_US
dc.identifier.urihttps://hdl.handle.net/2027.42/35204
dc.identifier.urihttp://www.ncbi.nlm.nih.gov/sites/entrez?cmd=retrieve&db=pubmed&list_uids=15706617&dopt=citationen_US
dc.description.abstractIn vivo microdialysis sampling was coupled to capillary liquid chromatography (LC)/electrospray ionization quadrupole ion trap mass spectrometry (MS) to monitor [Met]enkephalin and [Leu]enkephalin in the striatum of anesthetized and freely–moving rats. The LC system utilized a high-pressure pump to load 2.5 µl samples and desalt the 25 µm i.d. by 2 cm long column in 12 min. Samples were eluted with a separate pump at ∼100 nl min −1 . A rapid gradient effectively separated the endogenous neuropeptides in 4 min. A comparison was made for operating the mass spectrometer in the MS 2 and MS 3 modes for detection of the peptides. In standard solutions, the detection limits were similar at 1–2 pM (2–4 amol injected); however, the reproducibility was improved with MS 3 as the relative standard deviation was <5% compared with 20% for MS 2 for 60 pM samples. For dialysate solutions, reconstructed ion chromatograms and tandem mass spectra had much higher signal-to-noise ratios in the MS 3 mode, resulting in more confident detection at in vivo concentrations. The method was successfully used to monitor the peptides under basal conditions and with stimulation of peptide secretion by infusion of elevated K + concentration. Copyright © 2005 John Wiley & Sons, Ltd.en_US
dc.format.extent192000 bytes
dc.format.extent3118 bytes
dc.format.mimetypeapplication/pdf
dc.format.mimetypetext/plain
dc.language.isoen_US
dc.publisherJohn Wiley & Sons, Ltd.en_US
dc.subject.otherChemistryen_US
dc.subject.otherAnalytical Chemistry and Spectroscopyen_US
dc.titleCapillary liquid chromatography with MS 3 for the determination of enkephalins in microdialysis samples from the striatum of anesthetized and freely–moving ratsen_US
dc.typeArticleen_US
dc.rights.robotsIndexNoFollowen_US
dc.subject.hlbsecondlevelChemistryen_US
dc.subject.hlbtoplevelScienceen_US
dc.description.peerreviewedPeer Revieweden_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USAen_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USAen_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USAen_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USAen_US
dc.contributor.affiliationumDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109-1055, USA ; Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, USA ; Department of Chemistry, University of Michigan, 930 N. University Avenue, Ann Arbor, Michigan 48109-1055, USA.en_US
dc.identifier.pmid15706617en_US
dc.description.bitstreamurlhttp://deepblue.lib.umich.edu/bitstream/2027.42/35204/1/733_ftp.pdfen_US
dc.identifier.doihttp://dx.doi.org/10.1002/jms.733en_US
dc.identifier.sourceJournal of Mass Spectrometryen_US
dc.owningcollnameInterdisciplinary and Peer-Reviewed


Files in this item

Show simple item record

Remediation of Harmful Language

The University of Michigan Library aims to describe its collections in a way that respects the people and communities who create, use, and are represented in them. We encourage you to Contact Us anonymously if you encounter harmful or problematic language in catalog records or finding aids. More information about our policies and practices is available at Remediation of Harmful Language.

Accessibility

If you are unable to use this file in its current format, please select the Contact Us link and we can modify it to make it more accessible to you.