Now showing items 1-8 of 8
Analysis of cumulative strain in tendons and tendon sheaths
(Elsevier, 1987)
Twenty-five fresh frozen flexor digitorum profundus tendons stratified by sex were subjected to uniaxial step stress and cyclic loads in twelve intact human cadaver hands. By attaching specially designed clip strain gage ...
A biomechanical model of the lumbosacral joint during lifting activities
(Elsevier, 1985)
A biomechanical model of the lumbosacral region was constructed for the purpose of systematically studying the combined stresses and strains on the local ligaments, muscles and disc tissue during sagittal plane two-handed ...
The mechanical properties of human tibial trabecular bone as a function of metaphyseal location
(Elsevier, 1983)
Experimental determination of the elastic modulus and ultimate strength of human tibial trabecular bone as a function of metaphyseal location is presented.A 1 cm cubic matrix with planes parallel to the subchondral plate ...
The mechanical properties of trabecular bone: Dependence on anatomic location and function
(Elsevier, 1987)
In 1961, Evans and King documented the mechanical properties of trabecular bone from multiple locations in the proximal human femur. Since this time, many investigators have cataloged the distribution of trabecular bone ...
The limitations of canine trabecular bone as a model for human: A biomechanical study
(Elsevier, 1989)
Distal canine femurs were sectioned into 8mm cubic specimens. Orthogonal compression tests were performed to preyield in two or three directions and to failure in a third. Apparent density and ash weight density were ...
Fatigue failure of cortical bone screws
(Elsevier, 1983)
An experimental study of the fatigue life of cortical bone screws under conditions which simulated in vivo usage was performed. The two most important factors influencing fatigue life were axial screw tension (the force ...