Scan of specimen UMMZ:herps:242683 (NOTOSCINCUS ORNATUS) - Pelvic. Raw Dataset includes 1601 TIF images (each 797 x 484 x 1 voxel at 0.01437728 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen UMMZ:herps:242683 (NOTOSCINCUS ORNATUS) - Pelvic. Reconstructed Dataset includes 0.014377 TIF images (each 797 x 484 x 1 voxel at 0.014377 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen UMMZ:herps:242683 (NOTOSCINCUS ORNATUS) - Pectoral. Raw Dataset includes 1601 TIF images (each 1292 x 375 x 1 voxel at 0.01437728 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen UMMZ:herps:242683 (NOTOSCINCUS ORNATUS) - Pectoral. Reconstructed Dataset includes 0.014377 TIF images (each 1292 x 375 x 1 voxel at 0.014377 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen ummz:herps:242664 (LERISTA BIPES) - Pelvic. Raw Dataset includes 1601 TIF images (each 531 x 540 x 1 voxel at 0.0189237 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen ummz:herps:242664 (LERISTA BIPES) - Pelvic. Reconstructed Dataset includes 0.018924 TIF images (each 531 x 540 x 1 voxel at 0.018924 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen ummz:herps:242664 (LERISTA BIPES) - Pectoral. Raw Dataset includes 1601 TIF images (each 346 x 968 x 1 voxel at 0.0189237 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen ummz:herps:242664 (LERISTA BIPES) - Pectoral. Reconstructed Dataset includes 0.018924 TIF images (each 346 x 968 x 1 voxel at 0.018924 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen ummz:herps:242644 (CTENOTUS PIANKAI) - Pelvic. Raw Dataset includes 1601 TIF images (each 920 x 1547 x 1 voxel at 0.01337075 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen ummz:herps:242644 (CTENOTUS PIANKAI) - Pelvic. Reconstructed Dataset includes 0.013371 TIF images (each 920 x 1547 x 1 voxel at 0.013371 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen ummz:herps:242644 (CTENOTUS PIANKAI) - Pectoral. Raw Dataset includes 1601 TIF images (each 1364 x 568 x 1 voxel at 0.01337075 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen ummz:herps:242644 (CTENOTUS PIANKAI) - Pectoral. Reconstructed Dataset includes 0.013371 TIF images (each 1364 x 568 x 1 voxel at 0.013371 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen UMMZ:herps:203362 (LERISTA ORIENTALIS) - Pelvic. Raw Dataset includes 1601 TIF images (each 934 x 793 x 1 voxel at 0.01246573 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen UMMZ:herps:203362 (LERISTA ORIENTALIS) - Pelvic. Reconstructed Dataset includes 0.012466 TIF images (each 934 x 793 x 1 voxel at 0.012466 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
Scan of specimen UMMZ:herps:203362 (LERISTA ORIENTALIS) - Pectoral. Raw Dataset includes 1601 TIF images (each 839 x 500 x 1 voxel at 0.01246573 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction. and Scan of specimen UMMZ:herps:203362 (LERISTA ORIENTALIS) - Pectoral. Reconstructed Dataset includes 0.012466 TIF images (each 839 x 500 x 1 voxel at 0.012466 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.
CHIME provides accurate measurements while enabling inter-spacecraft calibration in constellation missions, offering a significantly more affordable alternative to traditional magnetometers without compromising measurement quality. The development of CHIME is motivated by the high number of magnetometers needed in spacecraft constellations that require a cost-effective commercial solution, as traditional, precise magnetometers are expensive and require complex ground and on-orbit calibration methods that depend on geomagnetic models or special conditions.
CHIME Accuracy Calibration:
- Various PNI RM3100s were used for data collection, each specified when used and how
- Ground CHIME was used for experiments (50 turns per axis, hand wound)
- Bartington HC1 500 mm Helmholtz coil was used for calibration baseline experiments.
- Python 3.7+
Coil Homogeneity Simulations:
- Python 3.7+
Optimal Calibration Pulse Parameters:
- Python 3.7+
- ESA Swarm Simulation Data 50 Hz: Level 1B MAGx_HR ( https://swarm-diss.eo.esa.int).
- ESA Swarm Simulation Data 1 Hz: Level 1B MAGx_LR.
CHIME Calibration Accuracy Across Orbital Environments:
- Python 3.7+
- ESA Swarm Simulation Data 50 Hz: Level 1B MAGx_HR ( https://swarm-diss.eo.esa.int).
Comparison Simulations of Single Sensor Attitude Indepedent Calibration Methods:
- Python 3.7+
- ESA Swarm Simulation Data 50 Hz: Level 1B MAGx_HR ( https://swarm-diss.eo.esa.int).
Definitions:
CHIME- protagonist of the dataset and accompanying manuscript, the self-calibrating magnetometer
Scale Factor (SF), Non-Orthogonality (NO)- forms of magnetic sensor error
PNI RM3100- internal magnetic sensor in CHIME
Bartington HC1 Coil- calibration tool for the RM3100 and CHIME, a Helmholtz coil itself.
ESA - European Space Agency and Updates:
- March 2025: Changes to simulated calibration methodology, completed before publication initial submission or peer-review
Dorman, C.J., Vata, J., Ojeda, L. V., Moldwin, M.B., The CHIME Magnetometer: A Self-Calibrating Approach for Enhanced Accuracy in Spaceborne Applications, Forthcoming.
Scan of specimen UMMZ:herps:170644 (LERISTA MUELLERI) - Pectoral. Reconstructed Dataset includes 0.013840 TIF images (each 396 x 643 x 1 voxel at 0.013840 mm resolution, derived from 1601 scan projections), xtek and vgi files for volume reconstruction.