This publication contains anonymized SPECT/CT scans of two patients. Patient scans were taken at 4 different time points in the week following a therapeutic dose of Lu-177 DOTATATE. Both the SPECT and the co-registered CT are provided. All images are in DICOM format.
This publication contains anonymized planar whole body images of two patients. Patient scans were taken at 4 different time points in the week following a therapeutic dose of Lu-177 DOTATATE. Both anterior and posterior views are provided. All images are in DICOM format.
This publication contains anonymized diagnostic imaging scans of two patients. The images provided are pre-therapy scans used by clinicians for diagnosis and for selecting patients for treatment with Lu-177 DOTATATE. Multiple imaging modalities are present including diagnostic CT, MRI, and Ga68 PET, depending on the selected patient. All images are in DICOM format.
We conducted a search through BioMed Central's 54 medicine and public health journals that provide OPR documentation in order to identify systematic review papers published in 2017. For each article we determined if OPR data, reviewer and author comments, were accessible. If so, we assessed the search methodology and reporting quality of the search process with a grading rubric based on PRISMA and PRESS standards, and then mined peer reviewer comments for references to the search methodology.
This .stl file represents the largest vessels of the cerebral circulation, specifically around the Circle of Willis. The file was created from a Computed Tomography Angiography (CTA) of a relatively healthy patient. It consisted of a 512 x 512 x 709 voxel image with a resolution of 0:35 mm x 0:35 mm x 0:5 mm.
The model includes the basilar artery (1), left and right internal carotid arteries (2, and 3), left and right anterior cerebral arteries (4, and 5), left and right middle cerebral arteries (6, and 7), left and right posterior cerebral arteries (8, and 9), and various communicating arteries (10, 11, and 12).
N. Wilson, K. Wang, R. Dutton, C.A. Taylor, "A software framework for creating patient specific geometric models from medical imaging data for simulation based medical planning of vascular surgery", Medical Image Computing and Computer-Assisted Intervention MICCAI 2001, Springer, 2001, pp. 449–456. doi: 10.1007/3-540-45468-3_54 and N. Xiao, J.D. Humphrey, C.A. Figueroa, "Multi-Scale Computational Model of Three-Dimensional Hemodynamics within a Deformable Full-Body Arterial Network”, Journal of Computational Physics, 2013, Vol 244, pp. 22-40. doi: 10.1016/j.jcp.2012.09.016
Please refer to the "README.txt" for more details., MATLAB R2018a (Mathworks, Natick, MA, USA) was used to process this data., and Excel (Microsoft Office) was used to store survey data on the comfort of both systems and also to provide absolute and relative intraobserver variablities for the DM device.
Comparison of anorectal function measured using wearable digital manometry and a high resolution manometry system Attari A, Chey WD, Baker JR, Ashton-Miller JA (2020) Comparison of anorectal function measured using wearable digital manometry and a high resolution manometry system. PLOS ONE 15(9): e0228761. https://doi.org/10.1371/journal.pone.0228761
Interest in quantitative imaging of Y-90 is growing because transarterial radioembolization (RE) with Y-90 loaded microspheres is a promising and minimally invasive treatment that is FDA approved for unresectable primary and metastatic liver tumors. These cancers are a leading cause of cancer mortality and morbidity. Radioembolization is a therapy that irradiates liver tumors with radioactive microspheres administered through a microcatheter placed in the hepatic arterial vasculature. Radioembolization is based on the principle that healthy liver and tumor are mainly vascularized by the portal vein and the hepatic artery respectively. As a result, radioactive microspheres are preferentially located in the lesions after they are administered via the hepatic artery.
Van, B. J., Dewaraja, Y. K., Sangogo, M. L., & Mikell, J. K. (2021). Y-90 SIRT: Evaluation of TCP variation across dosimetric models. EJNMMI Physics, 8(1), 45. https://doi.org/10.1186/s40658-021-00391-6
Interest in quantitative imaging of Y-90 and Lu-177 is growing due to their increased use as minimally invasive treatments for primary and metastatic tumors such as HCC and NETs. Accurate quantification of the 3D activity distribution for voxel-level dosimetry requires SPECT/CT and PET/CT imaging. This collection provides research access to anonymized PET/CT and SPECT/CT scans along with the relevant lesion/organ contours taken from University of Michigan clinical research studies of selected patients undergoing radionuclide treatments. All patients signed an informed consent to participate in the research studies. See the readme in each dataset for information on use and citation of this data.
The two R codes are related to the feasible balance region calculations for Figures 2, 3, and 4 in the paper.
The MATLAB codes are related to the simulations of the recoverable initial quasi-static states, the results of which are shown in Figure 5 of the paper.
Shahshahani, P. M., & Ashton-Miller, J. A. (2020). On the importance of the hip abductors during a clinical one legged balance test: A theoretical study. PLOS ONE, 15(11), e0242454. https://doi.org/10.1371/journal.pone.0242454
This data and scripts are meant to test and show that seizure onset dynamics can be modulated using anti-epileptic drugs. A zip file is included that contains all waveform data, MATLAB processing scripts, and metadata. The MATLAB scripts allow for visual review validation and objective feature analysis. The file includes various README files explaining the scripts and their relationships in greater detail.